THIS IS THE BEST CLINICAL REFRACTOMETER FOR THE MONEY! IT MATCHES THE ACCURACY OF UNITS THAT COST 2 AND 3 TIMES AS MUCH, BUT WITH MUCH MORE CONVENIENCE! DIP. READ. DONE! ATAGO has responded to the demand for a "Dip-type" refractometer by Hospitals, Clinics, Athletic Trainers & Coaches, Drug Testing Facilities and Probation Officers nationwide. Simply Dip or Touch the sensor to the sample for quick & easy measurement of Urine Specific Gravity. The PEN-Wrestling has been specifically engineered to meet the needs of all clinical testing facilities and programs. New design developments allow the tester to perform measurements with a simple "dip and touch" motion. This dip-in model is the most convenient unit available for quick, accurate readings. The practical design is also safer and hassle-free when it comes to cleanup. PEN-Wrestling - Urine SG: 1.0000-1.0600 - Minimum Scale: 0.0001 - Accuracy: ±0.0010 - Temp Compensation Range: 10 - 35° C · Light & Compact: The PEN-Wrestling allows for two types of measuring, based on sample size! · Digital Display: Easy and accurate readings, without user interpretation! · Fast & Easy: Measures in 2 seconds! · Automatic Temp. Compensation: No temperature conversion charts! · Water Resistant (Body - IP65, Prism Head - IP67): Run it under the faucet for fast and easy cleanup! · Zero-set with Water: No standard liquids required! · 8000 Measurements: From a single alkaline AAA battery!
The PAL-10S is a digital hand-held compact refractometer to measure urine S.G. To operate it, simply place a drop of urine on the prism top and press the "Start"key. Then, the urine S.G. value will be displayed on the LCD instantly.
Tanita's best-selling body composition analyzer Using our patented “foot-to-foot” BIA technology, the T300 determines body composition accurately in less than ten seconds. A portable design. Separate display head can be placed on a desktop in or out of the subjects view. Method of Measurement BIA (bio-electrical impedance analysis) Max. Capacity 440 lb Graduation Display 0.2 lb LCD Platform Dimensions 13.5" x 12.0" x 3.5" Unit Weight 17.5 lb Power Supply AC adapter (included) Printer Thermal
The fact that body components vary widely in their percentage relationship to total weight is the fundamental limitation to interpreting body weight. If the real problem is obesity rather than mere overweight, overweight and fatness must be dissociated to be understood properly. The most direct,simple, and accurate method for estimating leanness-fatness is measuring the thickness of skinfolds by constant-tension calipers. The Lange Skinfold Calipers manufactured by Beta Technology Inc., are specifically designed for the simple, accurate measurement of subcutaneous tissue. The Lange Caliper incorporates the recommended principles for standardized usage in nutrition, fat distribution, child growth, anthropomorphic studies, and other applications. It is important to use calipers in which the pressure is built into the instument itself and is relatively constant from reading to reading and over the range of skinfold thicknesses studied. Early models of calipers were unsatisfactory in that spring-loaded tension was very low at small openings but increased rapidly as the jaws of the calipers were opened. Experience has shown that caliper pressure of about 10 gm./sq. mm. is preferable to a very low or very high pressure and that it be constant over a range of openings from two to at least 40 mm. For the purposes of standardization, this pressure that has been recommended irrespective of the design of the caliper itself, with a contact surface from 20-40 sq. mm., depending on the shape of the surface. Data obtained with skinfold calipers has been found to agree with measurements obtained from roentgenograms of soft tissues. In turn, these determinations of subcutaneous fat have been correlated with calculations of total body fat obtained by other methods. -NWCA-
Ultrasound body composition and more...
Urinalysis 4S CHECK - (100 strips)- Glucose/Protein/PH/Specific Gravity This product is FDA approved and has over 2 years shelf life -NWCA-
This holster is the perfect companion for your MISCO Palm Abbe Digital Refractometer. The holster is constructed from the heaviest grade ballistic nylon and features a weather-resistant cover with Velcro closure. The extra-strong J-hook flex clip fits securely around a belt for added stability. Alternatively, the holster may be hooked to waistbands, pockets, or straps. Multiple pockets and accessory loops are intended for carrying everything you need in the field; such as pipettes, a pen, a small notebook, and even spare batteries (batteries not included).
Need proof? Our rugged Proof Case is water-proof, crush-proof, dirt-proof, dust-proof, drop-proof, rain-proof, snow-proof, sink-proof, even goof-proof. It is perfect for providing an additional level of protection when you use your Palm Abbe in demanding environments or when you just want to know that your instrument is safely stored. The virtually indestructible case has a fitted foam insert that cushions the Palm Abbe in the event of rough handling. Two heavy-duty latches secure the lid against an integral O-ring providing a waterproof seal to 100 feet (30.5 meters) under water.
One-piece molded, polyethylene (LDPE) plastic transfer pipettes. These disposable pipettes are unbreakable and reduce the risk of cross contamination of samples. They deliver repeatable, uniform drops and are ideal for use with the MISCO Palm Abbe Digital Refractometer and the MISCO Abbe Max Laboratory Refractometer. Packaged 1,000 to a box.